Luoyang Songdao Induction Heating Technology

POSITION:HOME > NEWS >

What is the overvoltage protection when the smelting furnace is feeding?

Update Time: 2019-01-25 09:12:14

What is the overvoltage protection when the smelting furnace is feeding?

Main reasons for overvoltage:

A workpiece and coil fire or coil and oxide skin fire

Overhaul: adjust the gap between the coil and the workpiece, clean the scale

B. Inductive coil part, capacitor part, the main circuit is connected to the copper bar screw loosely fired

Overhaul: tightening screws

C. Inverter thyristor has one (two) damage

When the inverter thyristor is damaged by one (two), the angle of observation from the meter head (inverter lead angle) is greater than or equal to 2 , and the ratio of DC current to DC voltage is much larger than normal.

Overhaul: Replace the thyristor

D inverter lead angle adjustment is too large

Overhaul: Re-adjust the front angle of the inverter, it should be (1.5)

E inverter resistance and absorption absorption part of the fault I am an outside electrician repair continuous casting crane, not the intermediate frequency electrician just learned some intermediate frequency power supply know, I hope to help you