2T induction melting furnace configuration selection method
Serial number |
name |
content |
Remarks |
1 |
Intermediate frequency power supply |
2T induction melting furnaceintermediate frequency power cabinet. (Including: power frequency power supply line knife isolation switch, air circuit breaker 1600A two sets; filter reactor two sets; double pulse rectification fast-melt protection; 12-pulse rectification system; inverter system; all-digital main control board; two furnace body Leakage furnace alarm system; low-voltage side power meter for melting power consumption metering device; indicating instrument and auxiliary device, etc.). 2. Compensation capacitor cabinet.
|
Reactor copper tube size: 14*12*2 Rectifier thyristor: KP800A/2000V. Inverter thyristor: KK2000A/1600V Total compensation capacitor capacity: 20000kvar Capacitor Model: RFM1.2-2000-0.5S |
2 |
Steel shell melting furnace body |
Furnace shell, fixing frame, furnace cover, induction coil, yoke, water distributor group, tilting furnace mechanism. |
2 sets |
3 |
Hydraulic power station |
Double motor double oil pump |
1 set |
4 |
Inclined table |
Independent control of each furnace body |
1 set |
5 |
Water cooled cable |
SD500 |
2 sets (8 pieces) |
6 |
Model |
|
2 |
7 |
Changing furnace |
Copper row switch |
|
8 |
Copper row |
Connection: 1, intermediate frequency power supply and capacitor cabinet; 2, slot road; 3, power frequency incoming copper bus. |
The power frequency incoming copper busbar is the upper incoming line mode. Power frequency copper row: 5*50mm IF copper row: 5*120mm Channel copper row: 5*200mm Copper row with cooling copper tube not less than 14*16 mm The power frequency, intermediate frequency, and copper busbars in the cabinet are processed by tin plating. |
9 |
Rectifier transformer (supporting facilities) |
ZPS-1500/10 six-phase output |
1 set |
10 |
Cooling water system (supporting facilities) |
Fully enclosed cooling tower |
1 set |
11 |
spare parts |
Main control board, rectification, inverter thyristor, fast-melting, RC absorption components. |
Main control board: 1 block; rectified thyristor: 1; inverter thyristor: 2; fast-melting: 2; RC absorption components: 2 sets. |