Main introduction of 1 ton induction melting furnace
one. 1 ton induction melting furnace equipment composition
One IF main cabinet , with an appearance of 1900mmX900mmX1400mm;
A capacitor cabinets , exterior 1500 mm X700 mm X700 mm;
Two 1 ton furnace bodies , with an appearance of 1400mmX1400mmX1300mm;
One tilting furnace control box, 200 ㎜ X300 ㎜ X400 ㎜;
Two reducers and two brackets;
One crucible mold;
Two water-cooled cables;
The weight of each intermediate frequency equipment: about 4500 kg.
The total volume of each intermediate frequency equipment: about 14 cubic meters.
two. Technical parameters of 1 ton induction melting furnace :
Device model: KGPS600-0.8
Rated input voltage : 380V ;
Input power frequency: 50HZ ;
Input power phase number: 3 phases;
Rated input current: 960A ( 320m ㎡ copper core cable is recommended );
Rated output power: 600KW
Rated output frequency: 0.8KHZ ± 20% ;
Rated output voltage : 1500V
Number of output phases: 1 phase ;
Rated capacity of electric furnace: 1 ton;
Melting rate: 1.0 tons / hour;
Cooling water consumption: 15 tons / hour;
Power supply (recommended): 700KVA
1 ton induction melting furnace performance description
1-2 Main control board: (wave soldering - constant power circuit) The main control board adopts chip integrated circuits imported from the United States.
●The rectifier trigger does not need any adjustment, has high reliability, and has a phase sequence adaptive circuit.
●The inverter adopts sweep frequency zero voltage start, with heavy load start function.
●The frequency tracking circuit adopts the average sampling scheme, which improves the anti-interference ability of the inverter.
●The inverter circuit is also equipped with an automatic inverter angle adjustment circuit, which can automatically adjust the matching of load impedance.
1-3 Protection and control: The internal functions of the main control board include
● Rectifier phase shift trigger, ● Three-phase phase sequence adaptive,
●Inverter trigger, ●Inverter lead angle lock,
●Inverter repeated start, ●Overcurrent protection,
●Overvoltage protection, ●Lack phase protection,
●Water pressure undervoltage protection, ●Control panel undervoltage protection, etc.
1-5 External power cord: The external power frequency power cord enters from the top of the intermediate frequency power cabinet , and each cabinet and furnace body requires the nearest grounding wire. 1-7 Power adjustment method: A power adjustment knob is installed on the panel of the intermediate frequency power supply cabinet. The output power of the whole machine can be adjusted arbitrarily.
1-8 Main circuit copper bars: The main circuit in the power cabinet is connected with high-purity copper plates, and the fastening points are completely stainless steel.
1-9 cabinet shell color: milky white and medium blue.
2. The structure of the smelting furnace body
The 2-1 furnace shell is of aluminum alloy structure.
2-2 The induction coil is wound by an annealed square oxygen-free high-purity copper tube, and is made through the main processes of pickling, saponification, baking, dipping, and drying, and passes through a water pressure 5 times the normal pressure ( 2MPa ) The test is completed.
2-3 Tilting furnace mechanism: mechanical tilting device, which is composed of a motor and a worm gear reducer. It can be electrically operated or manually tilted in the event of a sudden power failure. The maximum inclination angle of the furnace body is 95 °.
2-4 Capacitor cabinet: The capacitor and the cabinet body are installed with secondary insulation, the copper bar of the tank circuit is made of square oxygen-free pure copper pipe, and the cooling water hose is made of pressure-resistant PVC rubber hose.
3. Cooling water system of 1 ton induction melting furnace (provided by the party who excavates the pool)
1. Technical indicators:
Cooling water inlet temperature: 5 ~35 ℃
Outlet temperature of cooling water: ≤ 55 ℃
Cooling water pressure: 0.2MPa ~ 0.3MPa
Water supply pool: 40m3/h , the effective volume of the cooling pool is not less than 3 times of the water supply .
2. Cooling water quality requirements
PH value: 7 ~8.5
Total hardness: ≤ 10 degrees (each degree contains 10mgCaO in 1 liter of water )