Solution to the insulation problem of the induction coil of the metal melting furnace
The original induction coil insulation is first wrapped with glass ribbon, and then painted with insulating paint. After the equipment runs for a period of time, the glass ribbon will fall off and the insulation will deteriorate. Because the refractory material is the main induction coil lining, the main induction coil itself cannot be carried out without gaps. Re-wrap treatment. In severe cases, the refractory must be removed, and the induction coil must be taken out and re-wrapped.