What are the technical parameters of the 2.0T induction melting machine 1000 KW ?
project |
unit |
data |
Remark |
Electric furnace parameters |
|||
Rated Capacity |
t |
2.0 |
Liquid steel |
Maximum capacity |
t |
2.3 |
Liquid steel |
Maximum working temperature |
°C |
1750 |
|
Lining thickness |
mm |
120 |
|
Induction coil inner diameter φ |
M m |
840 |
|
Induction coil height |
mm |
1380 |
|
Electrical parameters |
|||
Transformer capacity |
KVA |
1000 |
|
Transformer primary voltage |
KV |
10KV |
|
Transformer secondary voltage |
V |
660, 660 |
12-pulse dual output |
Rated power of intermediate frequency power supply |
KW |
1000 |
12-pulse dual input |
Rated input current |
A |
955 |
|
DC voltage |
V |
890 |
|
DC |
A |
1120 |
|
Conversion efficiency |
% |
9 6 |
|
Startup success rate |
% |
100 |
|
The highest output voltage of the intermediate frequency power supply |
V |
2000 |
|
Rated working frequency |
Hz |
500 |
|
Power conversion efficiency |
% |
96 |
|
Working noise |
db |
≤75 |
|
Comprehensive parameters |
|||
Melting rate (heating to 160 0℃) |
T/h |
1.72 |
The time used to melt a furnace is related to the charging |
Melting power consumption (heating to 160 0℃) |
kW.h/T |
560 |
|
Hydraulic system |
|||
Hydraulic station capacity |
L |
600 |
|
Work pressure |
MPa |
11 |
|
Hydraulic medium |
|
Hydraulic oil |
|
Cooling water system |
|||
Cooling water flow |
T / h |
50 |
|
Water supply pressure |
Mpa |
0.25-0.35 |
|
Inlet water temperature |
°C |
5-35 |
|
Outlet temperature |
°C |
<55 |
|