Luoyang Songdao Induction Heating Technology

POSITION:HOME > NEWS >

2T induction melting furnace technical configuration selection table

Update Time: 2022-02-18 08:14:08

2T induction melting furnace technical configuration selection table

1. 2T induction melting furnace power supply parameter selection table

Serial number

project

unit

parameter

Remark

1

Transformer capacity

KVA

1500

10KV/2*660V /    6phase /50H△/ Ddoyn-11(ONAN)

2

Transformer primary voltage

KV

10

 

3

Transformer secondary voltage

V

660

 

4

rated power

KW

1250

power supply

5

Rated frequency

KHz

0.5

 

6

DC voltage

V

830

 

7

IF voltage

V

1200

 

8

Induction coil port voltage

V

2400

 

11

Rectifier

 

12 pulses

 

12

Inverter

 

 

8 thyristors

13

Power conversion efficiency

 

> 0.95

 

14

Power factor

 

> 0.92

Under rated power

15

Constant power output time

 

> 92%

During the melting cycle

16

Startup success rate

 

100%

 

17

Working noise

dB

≤85

1 meter away

2. 2T induction melting furnace

Serial number

project

Unit

Parameter

1

Rated Capacity

t

2.0

2

Rated working temperature

° C

1600

3. The melting rate and melting power consumption of 2T induction melting furnace ,

Serial number

project

Unit

Parameter

1

Melting rate (1600 ° C)

t/h

2.0

2

Melting power consumption (1600 ° C)

kwh/t

≤610

. 4, 2T induction melting furnace of the hydraulic system

Serial number

project

Unit

Parameter

1

Hydraulic station capacity

L

500

2

Work pressure

Mpa

10

3

input power 

KW

5.5

4

Work flow

L/ min

>45

5

The hydraulic oil supplier provides the model, and the buyer is responsible for the purchase and cost.

5. Technical requirements for supporting facilities of 2T induction melting furnace and special transformers

Serial number

project

parameter

1

Rated Capacity

1500KVA

2

Primary voltage

10KV±5% 3 phase 50HZ

3

Secondary voltage

660V*2

4

Primary current

86.6A

5

Secondary current

656A*2 /(660V)    

6

Connection group

Ddo-yn11

7

Impedance voltage

UK=6%

8

cooling method

ONAN

9

Pressure regulation method

3 gears no-excitation manual voltage regulation

10

Between network side and valve side

Add shielding to reduce the impact of harmonics on the network side

11

Safeguard

Heavy and light gas alarm, overpressure release and high oil temperature alarm

12

other

Low loss, high reliability, low noise, etc.

13

Winding

Copper core

14

Silicon steel sheet

WISCO produces a new oriented silicon steel sheet, model 30Q130.