3 T induction melting furnace technical parameter selection table
project |
unit |
3t melting furnace data |
Remark |
Electric furnace parameters |
|||
Rated Capacity |
t |
3.0 |
|
Maximum capacity |
t |
3.3 |
|
Lining thickness |
mm |
120 |
|
Induction coil inner diameter φ |
mm |
980 |
Sensor wall thickness 4mm |
Induction coil height |
mm |
1230 |
|
Maximum working temperature |
°C |
1750 |
|
Electrical parameters |
|||
Transformer capacity |
KVA |
2500 |
|
Transformer primary voltage |
KV |
10 |
|
Transformer secondary voltage |
V |
660 |
|
Rated power of intermediate frequency power supply |
KW |
2000 |
|
IF power supply output voltage |
V |
1300 |
|
Coil voltage |
V |
2600 |
|
Rated working frequency |
Hz |
500 |
|
Power conversion efficiency |
% |
96 |
|
Startup success rate |
% |
100 |
|
Comprehensive parameters |
|||
Melting rate ( heating up to 1600 ℃ ) |
t/h |
≥ 3.0 |
|
Melting power consumption ( heating up to 1650 ℃ ) |
KW • h/t |
610-640 |
|
Working noise |
db |
≤ 75 |
|
Hydraulic system |
|||
Hydraulic station capacity |
L |
350 |
Double pumps |
Work pressure |
MPa |
11 |
|
Hydraulic medium |
|
Hydraulic oil |
|
Cooling water system |
|||
Cooling water flow |
M3/h |
60 |
|
Inlet water temperature |
°C |
5-35 |
|
Outlet temperature |
°C |
35-55 |
|
Cooling water pressure |
MPa |
0.2-0.35 |
|