Key failure and maintenance of vacuum hot pressing furnace
Fault phenomenon |
the reason |
Method of exclusion |
1. The evacuation valve cannot be opened. |
(1) The front valve of the mechanical pump is not open |
Reference fault 2 |
(2) Is the compressed air pressure sufficient? |
(2) Requirements to reach 0.4MPa ~ 0.6MPa |
|
(3) The electromagnetic reversing valve of the rough valve does not work. |
Reference fault 3 |
|
(4) The stroke switch on the high vacuum valve is not compressed. |
(4) Adjust the position of the travel switch and the upper cover |
|
2, the mechanical pump front valve can not be opened |
(1) Pneumatic air source pressure is not enough |
(1) Up to 0.4MPa~0.6MPa |
(2) Electromagnetic reversing valve problem |
Reference fault 3 |
|
3, the magnetic control valve does not work |
(1) Turn on the electricity without suction action |
(1) The coil is damaged, replace the coil to replace the coil solenoid valve |
(2) Low working environment temperature |
(2) room temperature is higher than 45 ° C |
|
(3) The valve body is blocked |
(3) Clean the valve body by manual-automatic inspection, then inject the pump oil |
|
(4) Insufficient air pressure |
(4) 0.4MPa~0.6MPa |
|
4, the front valve can not be opened |
(1) Insufficient air pressure (2) Electromagnetic reversing valve work |
Reference fault 3 |
5, high vacuum valve can not be opened |
(1) The stroke switch on the rough valve is not pressed |
(1) Adjust the position of the travel switch and upper cover |
(2) Insufficient air pressure |
(2) 0.4MPa~0.6MPa |
|
(3) Electromagnetic reversing valve |
(3) Reference fault 3 |
|
(4) Insufficient vacuum (not reached vacuum gauge setting - upper limit) |
(4) The composite vacuum gauge (when working) is set to not less than 5Pa |
|
(5) The front valve is not open |
(5) The front valve is not open |
|
6 Roots pump does not start |
(1) Vacuum gauge J2 is not lit |
(1) The degree of vacuum does not reach 2000 Pa or less |
(2) 24V power supply burned off |
(2) Replace the 24V power supply |
|
(3) The air switch is not closed |
(3) Check no problem, close no switch |
|
7 molecular pump does not work |
(1) insufficient vacuum |
(1) When the molecular pump is fully started, the vacuum must be within 10Pa. |
8, the inflatable system does not work |
(1) The electromagnetic inflation valve does not operate |
(1) The coil is broken, the coil is replaced or the solenoid valve is replaced. |
9, the fan does not start |
(1) The air switch is not closed |
(1) Check no problem, close the switch |
(2) Motor damage |
(2) Repair or replace the motor |
|
10, the heating current is very uneven |
(1) The heating voltage is close to the rated value, the current is zero, and the heating is broken. |
(1) Connect or replace with molybdenum screws, nuts and molybdenum sheets |
(2) The heating belt is connected to the outer wall |
(2) partitioned with ceramic parts, padded, cleaned insulation |