E-Mail: firstfurnace@gmail.com
whatsapp:+8618037961302
Adress: Luoxin Industrial Park, Luoyang, HenanLarge AC Motors Terminal Rings
Medium-frequency welding of mo
Medium-Frequency Brazing Equip
Integral Brazing Process for t
Online Heating Equipment for T
Online Heating Equipment for A
Aluminum ingot heating equipme
Welding Equipment for Traction
Fully Digital Medium Frequency
Motor rotor end ring brazing e
Brazing equipment for hydro ge
Generator rod induction brazin
Hydropower generator stator ba
Large diameter steel pipe quen
Piston rod quenching and tempe
Grinding rod quenching and tem
induction heating machine 
How to choose the current frequency when the induction heating furnace heats the steel pipe ?
Induction heating furnace heating steel pipe is generally through heat, therefore, when selecting the frequency, the hot state current D heat should be greater than the thickness of the pipe wall .
Table 2 - . 8 shows the solenoid induction heating steel pipe and steel optimal frequency, and Table 2.9 lists (above the Curie point) heating the steel pipe wall thickness to obtain the best highest efficiency when various frequencies.
Table 2-8 The best frequency when the spiral tube inductor heats the steel pipe and the steel pipe
|
Tube outer diameter /mm |
Wall thickness/ mm |
Best frequency /kHz |
||
|
20 ℃ |
800 ℃ |
1200 ℃ |
||
|
Non-magnetic steel |
||||
|
12. 7 |
1 |
51 |
85 |
92 |
|
2 |
28 |
47 |
50 |
|
|
3 |
twenty one |
34 |
37 |
|
|
25.4 |
1 |
25 |
41 |
44 |
|
2 |
13 |
21 |
23 |
|
|
3 |
8.9 |
15 |
16 |
|
|
5 |
5.9 |
9. 8 |
11 |
|
|
50. The 8 |
1 |
12 |
20 |
22 |
|
2 |
6. 1 |
10. 1 |
11 |
|
|
3 |
4.2 |
6.9 |
7.5 |
|
|
5 |
2.6 |
4. 3 |
4.7 |
|
|
76.2 |
1 |
7.9 |
13.2 |
14.3 |
|
2 |
4 |
6.7 |
7.2 |
|
|
3 |
2.7 |
4.5 |
4.9 |
|
|
5 |
1.7 |
2. 8 |
3 |
|
|
102 |
1 |
5.9 |
9.9 |
10.6 |
|
2 |
3 |
5 |
5.4 |
|
|
3 |
2 |
3.4 |
3.6 |
|
|
5 |
1.2 |
2. 1 |
2.2 |
|
|
12.7 |
|
1.33 |
3.7 |
6. 3 |
|
|
0. 73 |
2 |
3.4 |
|
|
|
0. 54 |
1.5 |
2.5 |
|
Table 2-9 The best wall thickness for steel pipe heating to obtain the highest efficiency at various frequencies (when higher than the Curie point)
|
Frequency /Hz |
Diameter /mm |
|||||||||
|
5 |
10 |
20 |
50 |
100 |
200 |
300 |
500 |
10000 |
20000 |
|
|
50 |
|
|
|
|
|
|
25 |
15 |
7 |
3 |
|
150 |
|
|
|
|
|
25 |
10 |
5 |
2.1 |
1 |
|
500 |
|
|
|
|
20 |
5 |
2.5 |
1.5 |
0.75 |
0.3 |
|
1000 |
|
|
|
|
10 |
4 |
1.3 |
0.7 |
0.4 |
0. 15 |
|
2400 |
|
|
|
10 |
3 |
1.5 |
0.6 |
0. 3 |
0. 13 |
|
|
4000 |
|
|
|
5 |
2 |
0.8 |
0.3 |
0. 18 |
0. 07 |
|
|
10000 |
|
|
5 |
1.8 |
0.7 |
0. 35 |
0. 13 |
0. 08 |
|
|
|
70000 |
|
2 |
0.6 |
0.21 |
0. 11 |
|
|
|
|
|
|
440000 |
0.6 |
0.2 |
0. 09 |
|
|
|
|
|
|
|