E-Mail: firstfurnace@gmail.com
whatsapp:+86 13015583380
Adress: Luoxin Industrial Park, Luoyang, HenanLarge diameter steel pipe quen
Piston rod quenching and tempe
Grinding rod quenching and tem
induction heating machine 
High frequency induction heate
Quenching equipment for machin
Round steel end heating furnac
Steel pipe heat treatment prod
Square steel quenching and tem
Sucker rod quenching and tempe
Thickened petroleum steel pipe
Round steel quenching and temp
Steel pipe quenching and tempe
Steel plate quenching and temp
Induction Hardening Machine&nb
Flywheel ring gear high freque
5T Induction Melting Furnace
First, the 5T induction melting furnace consists of:
3000kw intermediate frequency power supply - capacitor cabinet - aluminum shell or steel shell furnace - hydraulic tilting furnace system - remote control box - ZXZ-N320T ( 70/250) closed loop cooling tower.
Second, the price of 5T induction melting furnace
The price of the 5T induction melting furnace is calculated according to the power of the intermediate frequency power supply and the volume of the furnace body. Different configuration prices vary. This price is for reference only. Contact us will have a very low price, please consult the specific price.Firstfurnace@gmail.com
Serial number |
Item name |
Specification model |
unit |
Quantity |
Price £¤ |
1 |
IF power cabinet |
3000KW/5T/500HZ |
station |
1 |
260000 |
2 |
Capacitor cabinet |
2 . 0 - 4 000-1S |
set |
1 |
100000 |
3 |
5T furnacesteel shell |
GW- 5T |
set |
1 |
250000 |
4 |
Water cooled cable |
LHSD- 600 |
set |
4 |
30000 |
5 |
Model |
5T furnace dedicated |
only |
1 |
3000 |
Total: £¤ 643,000 |
Third, the choice of 5T induction melting furnace related configuration
Intermediate frequency power supply |
Working form: rectifier series inverter series (SCR) 6- phase12- pulse ( one electric two furnace ) |
The cross-sectional area of the incoming copper bar : 1000mm2 copper row 100x10mm copper row within 10 meters. |
|
Cabinet shell: a rectifier cabinet Inverter cabinet a1500x4000x2200mm 1500x1500x2200mm |
|
Power efficiency ¡Ý98% Cabinet material: main frame carbon steel, cabinet door: aluminum alloy. |
|
Start mode: variable frequency buffer start |
|
Startup rate: 100% (including heavy load) |
|
Rated frequency: 3 0 0Hz -500Hz |
|
AC voltage: 575 V rectifier series |
|
DC voltage: 1550 V |
|
IF voltage: 3400v |
|
DC current: 2340 A |
|
Incoming AC current: 1900 A |
|
Input frequency: 50Hz |
|
Rectifier 2 ways in series and then parallel, inverter form:inverter parallel or inverter series |
|
Weight: 5000 KG or so |
|
Circulating water volume: closed - loop water cooling towerZXZ-N320T ( 70/250) |
|
Furnace body |
Rated capacity: 5 0 0 0KG |
Maximum capacity: 5300 KG |
|
Rated power: 3500 KW |
|
Frequency: 300 Hz |
|
Power factor: ¡Ý0.9 6 |
|
Working mode: one electric two furnace |
|
Melting time : 55 minutes ¡À 5% |
|
Working temperature: 1 550 ¡ãC |
|
Loading height: 1550 mm Hearth height: 1250mm |
|
Loading diameter: 910 mm (upper mouth) inner diameter of the ring: 1100mm ring copper tube is 40x70x8mm |
|
Loading diameter: 825 mm (lower) Inner diameter of the ring:1100mm |
|
Furnace copper tube: 55x65x8mm 15ÔÑ , weight 2500 , total length: 164 meters |
|
Maximum angle of the tilting furnace: 95¡ã |
|
Outlet mode: side outlet |
|
Yoke : Covering area 80% . Thickness: 0.35mm |
|
Tilting method: hydraulic |
|
Unit power consumption: 520 ¡À 5% kW.h/t 1550 ¡ã C |
|
Working voltage: 3400V |
|
Dimensions: |
|
transformer |
Rated capacity: 3150KVA a |
Primary voltage: 10KV |
|
Secondary voltage: 1500v |
|
One phase: 3 phase |
|
Secondary phase number: 6 phase 12 veins |
|
Output form: three ¡÷ three Y |
|
Hydraulic |
Hydraulic cylinder: |
Working pressure: 10Mpa |
|
Diameter: ¦µ 320 plunger cylinder |
|
Itinerary: 2 107mm |
|
3 flow: > 26L/Min |
|
Hydraulic station: |
|
Working pressure: 10Mpa |
|
Hydraulic pump: double pump double |
|
Form: Horizontal |
|
Capacity: 12 00L |
|
Console |
Mode: Electric (action indicator) |
Cooling water system |
Integrated layered tower closed - loop water cooling towerZXZ-N320T ( 70/250) |
Cooling capacity 18 0000 0 kcal/h cooling water volume 35 0m3/h Fan power 11 KW ¡Á 2 units Fan air volume 12 5000m3/h ¡Á2 Spray pump 190 m3/h ; 4 kw main motor 30kw Dimensions mm 53 00¡Á2 3 00¡Á 4910 (one size) |
|
Pipeline |
Pipe material: PPR, pipe diameter: DN125X2=DN250 , watersupply port DN65 , total length of water pipe within 30meters. The electrical control cabinet is within 5 meters of the power supply cabinet . |
5T induction melting furnace features :
1. Intelligent system, fast protection, durable thyristor, good starting performance, stable operation and convenient operation.
2 , the use of large copper discharge machine, increase the reactor power saving.
3 , induction melting furnace has over voltage, over current, water temperature, water pressure, short circuit, grounding and other protection systems, the operating panel has a working parameter display table , display various parameters of the working state, and there are faults, temperature and other indications.
4. What information does the customer need to provide to the supplier before purchasing the induction melting furnace?
1. Induction melting furnace should have space for layout, and it is necessary to provide the area and layout of the plant.
2. The customer needs to provide the capacity of the transformer, the magnitude of the incoming line voltage, and the frequency of the incoming line voltage.
3. The induction melting furnace requires water-cooling equipment, and the induction melting furnace configuration contains water-cooling equipment.
4. The furnace structure of the induction melting furnace has a steel shell furnace body and an aluminum shell furnace body, and the customer needs to specify the furnace body structure.
5. The power supply of the induction melting furnace is an intermediate frequency power supply. The circuit structure of the intermediate frequency power supply is divided into an inverter parallel connection and an inverter series structure. The inverter series structure is energy-saving, the power factor is 0.98, and the line is stable. The inverter parallel structure is of the common type with a power factor of 0.92, which requires the customer to specify the line structure.
Eight, a good way to correctly and quickly select the " 5T induction melting furnace "
1. Induction melting furnace transformer capacity selection
5T induction melting furnace should choose 3150KVA transformer. The secondary output voltage is 1000v
Selection basis: value of transformer capacity = value of induction melting furnace power supply x 1.2
The transformer is a rectifier transformer. In order to reduce the interference of harmonics, it is used as far as possible for the special plane, that is, one induction melting furnace is equipped with a rectifier transformer.
1. Selection of 5T induction melting furnace inlet voltage
5T induction melting furnace power is 3000kw using six- phase 12- pulse 1000 V , 50HZ industrial electricity
Selection basis: For medium frequency power supply for induction melting furnace below 1000KW , three-phase five-wire 380V and 50HZ industrial power are generally used . For induction melting furnaces above 1000KW , the focus is on using 660V - 1000v incoming voltage .
1. According to the capacity requirements, determine the induction melting furnace with large tonnage.
The capacity of the induction melting furnace can be determined by the weight of the individual pieces and the weight of the molten iron required for each working day .
The standard tonnage is as follows:
250kg induction melting furnace
500kg induction melting furnace
1T induction melting furnace
2 T induction melting furnace
3T induction melting furnace
5T induction melting furnace
4. Selection of 5T induction melting furnace body structure
The capacity of the 5T induction melting furnace is small. The recommended choice is: the furnace body of the hydraulic steel shell .
The aluminum alloy structure commonly known as the aluminum alloy structure with the reducer as the tilting furnace method. The induction melting furnace of the steel structure with the hydraulic cylinder as the tilting furnace is commonly called the steel shell furnace. The steel shell furnace is a steel structure, and the aluminum shell furnace shell material is an aluminum alloy .
Nine, 5T induction melting furnace energy consumption determination
The electric power of the induction melting furnace is larger and the power is saved. The energy consumption of the molten iron of the 5T induction melting furnace : 5 5 0KW.h/t , energy consumption of molten steel 6 0 0 KW.h/t .
Ten, how to choose the induction melting furnace lining material?
1. Induction melting furnace lining material is divided into acid lining material, alkaline lining material, neutral lining material, coil cement, root melting material, medium frequency electric furnace tonnage, product molding temperature is different, it is very important to choose the appropriate lining material. jobs.
2. Induction melting furnace is a molten steel furnace using alkaline lining material mainly for fused magnesia. The induction melting furnace is a molten iron furnace. The acid lining material is a refractory material for quartz coreless induction furnace, and the material is acidic.
11. How to increase the melting speed of the induction melting furnace?
1. Increase the power of the induction frequency melting furnace intermediate frequency power supply.
2. Choose a reasonable charge size and the correct feeding method.
3. Appropriate molten iron outlet temperature.