E-Mail: firstfurnace@gmail.com
whatsapp:+86 13015583380
Adress: Luoxin Industrial Park, Luoyang, HenanLarge diameter steel pipe quen
Piston rod quenching and tempe
Grinding rod quenching and tem
induction heating machine 
High frequency induction heate
Quenching equipment for machin
Round steel end heating furnac
Steel pipe heat treatment prod
Square steel quenching and tem
Sucker rod quenching and tempe
Thickened petroleum steel pipe
Round steel quenching and temp
Steel pipe quenching and tempe
Steel plate quenching and temp
Induction Hardening Machine&nb
Flywheel ring gear high freque
0.75 T medium frequency induction furnace configuration list
project |
Configuration one Aluminum shell furnace price: Steel shell furnace price: |
Configuration two Aluminum shell furnace price: Steel shell furnace price: |
Configuration three Aluminum shell furnace price: Steel shell furnace price: |
Configuration four Aluminum shell furnace price: Steel shell furnace price: |
system |
Jiangsu Zhenwu |
Jiangsu Zhenwu |
Jiangsu Zhenwu |
Jiangsu Zhenwu |
Transformer phase number |
6 phase |
6 phase |
6 phase |
6 phase |
Voltage |
380-450V |
450--500V |
500--550V |
500--550V |
Rectification |
Series |
Series |
Series |
Series |
Circuit breaker switch |
DW15-1200A |
DW15-1200A |
Zhengtai intelligent circuit breaker -1200A |
German intelligent ( extracting magnetic ) circuit breaker -1200A |
Line inductance |
800KW 6 Zhi |
1000KW 6 Zhi |
Moisture-proof insulation 1000KW 6 Zhi |
Moisture-proof insulation 1000KW 6 Zhi |
SCR KP |
800A/1800V 12 (silicon sea) |
1000A/1800V 12 (silicon sea) |
1000A/2500V 12 (Sichuan Haibei Group Supervision Motorcycle Special Thyristor) |
1200A/2500V 12 (Sichuan Haibei Group supervision brake thyristor) |
Thyristor water cooling frame KP |
13# double 6 sets |
13# double 6 sets |
13# double 6 sets ( import ) |
14# double 6 sets ( import ) |
Current shunt |
1500A/75mv 1 only |
1500A/75mv 1 only |
1500A/75mv 1 only |
1500A/75mv 1 only |
Reactor |
800KW one |
800KW one |
1000KW thick copper tube |
1000KW thick copper tube |
SCR KK |
1200A/1800 V 8 (silicon sea) |
1500A/1800 V 8 (silicon sea) |
800A/3500 V 16 (out of the silica sea) |
1200A/3500 V 16 (out of the silica sea) |
Thyristor water cooling frame KK |
13# double 4 sets |
14# double 4 sets |
14# double 8 sets ( import ) |
14# double 8 sets ( import ) |
Electric capacitor |
1.5-2000-0.5S 4 sets (Wei Wei brand) |
1.6-2000-0.5S 5 sets (ÉÏÓÝÅÆ) |
1.9-2500-0.5S 6 sets (ÉÏÓÝÅÆ) |
1.9-2500-0.5S 6 sets (ÉÏÓÝÅÆ) |
Water cooled cable |
2 260 sq. |
320 square 2 |
400 sq. 2 (soft copper heart) |
400 sq. 2 (soft copper heart) |
Voltage equalizing resistor |
Increase power200W10K 20 (import) |
Increase power 200W10K 20 (import) |
Increase power 200W10K 28 (import) |
Increase power 200W10K 28 (import) |
Rectifying absorbing capacitor |
Domestic 0.47uf three series 12 sets |
Taiwan 0.47uf three series 12 sets |
US imports 0.47uf three series 12 sets |
US imports 0.47uf three series 12 sets |
Inverter absorption capacitor |
Domestic 0.33uf three series 8 sets |
Taiwan 0.33uf three series 8 sets |
US imports 0.33uf three series 16 sets |
US imports 0.33uf three series 16 sets |
Resistor-capacitor absorption resistor |
(US imports) 150W10Europe 20 |
(US imports) 150W10 Europe 20 |
(US imports) 150W10 Europe 28 |
(US imports) 150W10 Europe 28 |
Internal copper row (MM) |
80*4 |
80*6 |
80*6 |
80*6 |
Inverter output copper bar(MM) |
80*6 |
80*8 |
80*8 |
120*6 |
And string in bronze |
80*6 |
80*6( |
150*8 |
150*8 |
Capacitor copper row |
50*3 |
50*4 |
50*4 |
50*4 |
Capacitor cooling copper tube |
30*30 |
30*40 |
30*40 |
30*40 |
Aluminum shell furnace standard |
Standard 0.75 tons |
Standard 0.75 tons |
Increase 0.75 tons |
Increase the height of 0.75 tons |
Steel shell furnace standard |
Simple 0.75 tons |
Simple 0.75 tons |
Specific increase of 0.75 tons |
Specific increase of 0.75 tons |
Steel shell furnace water pouring device |
315 shift mode or hydraulic system |
431 shift mode or hydraulic system |
Hydraulic system |
431 shift mode or hydraulic system |
Induction ring inner diameter |
600 |
600 ( higher type double subsidized cooling tube )three in three out cooling |
620 ( higher type double subsidized cooling tube ) three in three out cooling |
620 ( higher type double subsidized cooling tube ) three in three out cooling |
KP breakdown protection system |
no |
no |
Have |
Have |
KK breakdown protection alarm system |
no |
no |
Have |
Have |
KP water temperature protection system |
no |
no |
Have |
Have |
KK water temperature protection system |
no |
no |
Have |
Have
|
PLC computer operating system |
no |
no |
Already prepared port , can be modified with PLC site tracking power consumption misoperation alarm blocking |
Already prepared port , can be equipped with PLC remote monitoring and tracking power consumption misoperation alarm blocking |
External protection |
Have |
Have |
Have |
Have |
Equipment high temperature alarm |
Have |
Have |
Have |
If the customer has installed PLC, remote alarm emergency stop |