Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • 250kg medium frequency melting

    5T intermediate frequency melt

    3T intermediate frequency melt

    2T intermediate frequency melt

    1T intermediate frequency melt

     0.75T Intermediate Frequ

    0.5T intermediate frequency me

    Medium Frequency Induction Mel

    250kg induction melting f

    500kg medium frequency in

    5T Medium Frequency Induction

     5T Induction Meltin

     500kg induction mel

    induction melting furnace

    3T medium frequency induction

    2T frequency induction me

    1T Medium Frequency Induction

    Bar heating furnace

    300KG electromagnetic melting

    250 KG electromagnet

    200 KG electromagnet

    silver melting furnace

    Brass melting Furnace

    atomization milling equipment

    Platinum melting furnace

    Selection of common spare part

    Medium frequency copper meltin

    scrap copper melting furnace

    Electric furnace principle
        How to choose the appropriate inverter thyristor for IF power supply
    In the process of designing the intermediate frequency power supply, how to select the appropriate inverter thyristor according to the actual application can follow the following principles:
    1. According to the working frequency range of the intermediate frequency power supply:
    a) KK-type thyristors with a frequency of 100HZ---500HZ with a selected turn-off time of 20μs-45μs.
    b) KK-type thyristors with a frequency of 500HZ---1000HZ with a selected turn-off time of 18μs-25μs.
    c) KK-type thyristors with a frequency of between 1000 Hz and -2500 Hz with a selected turn-off time of 12 μs to 18 μs.
    d) The selected off-time of the frequency at 2500HZ---4000HZ is controllable at KKG type of 10μs-14μs.
    e) KA type thyristor with a frequency of 4000HZ---8000HZ with a selected off-time of 6μs - 9μs.
    2. According to the output power of the intermediate frequency power supply:
    According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times of the total current. Considering that there is sufficient margin, the thyristor of the same size as the rated current is usually selected.
    a) The thyristor with a power of 50 kW----100 kW with a selected current of 300 A/1400 V. (380V phase-in phase voltage)
    b) The thyristor with a selected current of 500A/1400V with a power of 100KW--250KW. (380V phase-in phase voltage)
    c) The thyristor with a selected current of 800A/1600V with a power of 350KW-400KW. (380V phase-in phase voltage)
    d) The thyristor with a selected current of 1500A/1600V with a power of 500KW--750KW. (380V phase-in phase voltage)
    e) A thyristor with a selected current of 1500A/2500V with a power of 800 KW to 1000 KW. (660V phase-in voltage)
    f) The thyristor with a selected current of 2000A/2500V with a power of 1200KW-1600KW. (660V phase-in voltage)
    g) A thyristor with a current of 2500A/3000V with a power of 1800KW-2500KW. (1250V phase voltage)