Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • 0.25T Intermediate Frequency F

    0.5T Intermediate Frequency Fu

    Medium Frequency Furnace

    2T Induction Melting Furnace

    1T Induction Melting Furnace

    500kg Induction Melting Furnac

    250kg Induction Melting Furnac

    Induction Melting Furnace

    3 T Induction Melting Furnace

    5T Induction Melting Furnace

    1T One Belt Two Intermediate F

    5T One Belt Two Intermediate F

    3T One Belt Two Intermediate F

    2T One Belt Two Intermediate F

    5T Parallel Intermediate Frequ

    5T Intermediate Frequency Furn

    5T Series Intermediate Frequen

    3T Series Intermediate Frequen

    2T Series Intermediate Frequen

    1T Series Intermediate Frequen

    0.5T Series Intermediate Frequ

    0.25T Series Intermediate Freq

    1T Parallel Intermediate Frequ

    2T Parallel Intermediate Frequ

    0.5T Parallel Intermediate Fre

    0.25T Parallel Intermediate Fr

    Parallel Intermediate Frequenc

    3T Intermediate Frequency Furn

    Electric furnace technical parameters
        


    Induction heating furnace temperature control principle and use method

    The schematic diagram is shown in the figure. The board includes two parts of temperature control, and the temperature control input signal uses a standard current signal of 0-20 mA. The current signal is taken out by the voltage signal of R52, and then the voltage of the W terminal is calculated. The integrated block U1D amplifies the output. The maximum value of the output voltage has the potential of the W terminal to determine the temperature control circuit. 20mA

    The flow signal is compared with the voltage of the external potential of the external potentiometer through R52. The differential pressure between the two is amplified by U1D, and the output voltage changes. The range of change is determined by R54 and R51. The time has been set at about 10 times, the voltage difference between UR52 and UW2 is 0.1V, and the voltage at the output of U1D should be about 1V. In normal operation, the output BH point is low, and after the temperature control is input, the output is high, and the output power of the intermediate frequency power supply is low. To achieve the purpose of temperature control. The temperature is determined by the high or low potential of the W terminal. Under normal circumstances, the high and low W values of the temperature indication can be adjusted accordingly.




    Copyright© 2007-2013 songdao Electric furnace manufacturing Co,.Ltd All Rights Reserved
    Tel:18037961302 Sales hot line ( 24 hours service): 18037961302
    E-Mail:firstfurnace@gmail.com
    Adress: Luoxin Industrial Park, Luoyang, Henan