Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • 0.25T Intermediate Frequency F

    0.5T Intermediate Frequency Fu

    Medium Frequency Furnace

    2T Induction Melting Furnace

    1T Induction Melting Furnace

    500kg Induction Melting Furnac

    250kg Induction Melting Furnac

    Induction Melting Furnace

    3 T Induction Melting Furnace

    5T Induction Melting Furnace

    1T One Belt Two Intermediate F

    5T One Belt Two Intermediate F

    3T One Belt Two Intermediate F

    2T One Belt Two Intermediate F

    5T Parallel Intermediate Frequ

    5T Intermediate Frequency Furn

    5T Series Intermediate Frequen

    3T Series Intermediate Frequen

    2T Series Intermediate Frequen

    1T Series Intermediate Frequen

    0.5T Series Intermediate Frequ

    0.25T Series Intermediate Freq

    1T Parallel Intermediate Frequ

    2T Parallel Intermediate Frequ

    0.5T Parallel Intermediate Fre

    0.25T Parallel Intermediate Fr

    Parallel Intermediate Frequenc

    3T Intermediate Frequency Furn

    Electric furnace industry news
        
    The main reasons for the capacitor burnout of the intermediate frequency furnace are as follows:

    1. In the absence of water, during the long-term use of the intermediate frequency electric furnace, it may cause scale in the cooling tube of the capacitor or the water inlet system may become clogged with impurities, causing the electric heating capacitor to overheat and burn out. Therefore, in the course of use, it is necessary to observe the flow of the cooling water of the electric heating capacitor. If there is abnormal flow, the corresponding measures should be taken;

    2. The intermediate frequency voltage is too high. In the long-term use of the intermediate frequency electric furnace, if the intermediate frequency electric furnace is adjusted too high, it is higher than the rated voltage of the electric heating capacitor (the rated voltage of the electric heating capacitor is 750V, 1200V, etc.), which will cause electric heating. Capacitor overvoltage breakdown. If this happens, you need to lower the intermediate frequency voltage or replace the electric heating capacitor with a high pressure rating.

    3. The cathode of the electric heating capacitor is grounded. If the electric heating capacitor is not well insulated during the use of the intermediate frequency electric furnace, the capacitor cathode grounding will cause the capacitor housing to break down. If this happens, the capacitor cabinet needs to be used. The insulation is reprocessed.