Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • 0.25T Intermediate Frequency F

    0.5T Intermediate Frequency Fu

    Medium Frequency Furnace

    2T Induction Melting Furnace

    1T Induction Melting Furnace

    500kg Induction Melting Furnac

    250kg Induction Melting Furnac

    Induction Melting Furnace

    3 T Induction Melting Furnace

    5T Induction Melting Furnace

    1T One Belt Two Intermediate F

    5T One Belt Two Intermediate F

    3T One Belt Two Intermediate F

    2T One Belt Two Intermediate F

    5T Parallel Intermediate Frequ

    5T Intermediate Frequency Furn

    5T Series Intermediate Frequen

    3T Series Intermediate Frequen

    2T Series Intermediate Frequen

    1T Series Intermediate Frequen

    0.5T Series Intermediate Frequ

    0.25T Series Intermediate Freq

    1T Parallel Intermediate Frequ

    2T Parallel Intermediate Frequ

    0.5T Parallel Intermediate Fre

    0.25T Parallel Intermediate Fr

    Parallel Intermediate Frequenc

    3T Intermediate Frequency Furn

    Industrial electric furnace technical information
        

    Furnace ring induction coil failure of intermediate frequency furnace

    The induction coil is the load of the intermediate frequency power supply and is also a furnace ring. It is made of a square copper tube with a wall thickness of 3 to 5 mm. Its common faults are as follows: the induction coil leaks, which may cause the coil to ignite between the turns, and must be repaired in time to run. The molten steel sticks to the induction coil, and the steel slag is hot and red, which will cause the copper tube to burn through and must be cleaned up in time. Induction coils are short-circuited between turns, and such faults are particularly prone to occur in small-medium-frequency induction heating furnaces because the furnace is small, subjected to thermal stress during operation or deformed during furnace, resulting in a short circuit between turns, and the fault is characterized by a large current. The frequency is higher than usual. Sometimes it is difficult to start. Check the troubleshooting carefully.


    Copyright© 2007-2013 songdao Electric furnace manufacturing Co,.Ltd All Rights Reserved
    Tel:18037961302 Sales hot line ( 24 hours service): 18037961302
    E-Mail:firstfurnace@gmail.com
    Adress: Luoxin Industrial Park, Luoyang, Henan