Contact
Tel: 18037961302
Sales hot line ( 24 hours  service): 18037961302

E-Mail: firstfurnace@gmail.com

whatsapp:+8618037961302

Adress: Luoxin Industrial Park, Luoyang, Henan
  • Products
  • Gear hardening machine

    Large diameter steel pipe quen

    Piston rod quenching and tempe

    Hand-held induction heater

    Grinding rod quenching and tem

    Induction forging machine

    induction heating machine 

    Induction heater

    High frequency induction heate

    Super audio induction heating

    Super audio induction heating

    Guideway quenching integrated

    Quenching equipment for machin

    Round steel end heating furnac

    Steel pipe heat treatment prod

    Square steel quenching and tem

    Sucker rod quenching and tempe

    Thickened petroleum steel pipe

    Round steel quenching and temp

    Steel pipe quenching and tempe

    Steel plate quenching and temp

    Induction Hardening Machine&nb

    Flywheel ring gear high freque

    Oil drill pipe quenching and t

    Iron induction furnace

    Aluminum melting furnace

    Copper melting furnace

    Small steel melting furnace

    Induction Heating Related Products(相关产品)
        

    Maintenance and overhaul of induction melting furnace

    Reasonable use, correct operation and meticulous maintenance are important guarantees for the safe operation of induction melting furnaces and avoiding failures. In the continuous operation of the production line, the equipment must be well maintained.

    Frequently eliminate the dust in the power distribution cabinet, especially the intermediate frequency power cabinet should be cleaned up.

     

    Frequently check whether the water pipes are tightly tied and remove the scale on the inner wall of the cooling water pipes in time to ensure sufficient water flow. The aging and cracked water pipes must be replaced in time. The dirt in the cooling pool must be removed in time to avoid clogging the water pipes.

    The device shall be inspected and repaired regularly, and the bolts and nut connections of each part of the device shall be inspected and tightened regularly.

    Check the water pressure gauge regularly.

    Frequently check whether the tank circuit wiring is in good condition and whether the insulation is reliable. The tank circuit of the intermediate frequency power supply is prone to faults such as "short circuit" and "discharge" due to the harsh working environment. Therefore, strengthening the maintenance of bus harnesses, water-cooled cables, sensors, etc. is an important part of ensuring the safe operation of the system.